Previous  Next  Search
North Baja Pipeline, LLC
FERC Gas Tariff
Original Volume No. 1

Original Sheet No. 111

                   GENERAL TERMS AND CONDITIONS OF SERVICE
                                 (Continued)

4.  MEASUREMENTS

    4.1   Metering:  The gas shall be metered by one or more orifice, 
          turbine, ultrasonic, displacement or other-type meters, at the 
          discretion of NBP. All meters shall be installed and maintained, 
          and volumes shall be measured, in accordance with applicable 
          A.G.A. standards for the meter in question.

    4.2   Specific Gravity:  The specific gravity of the gas delivered 
          hereunder shall be determined from the read-outs of continuously 
          operating measuring instruments.  The method shall consist of one 
          of the following:

          (a)  gravitometer

          (b)  gas chromatography

           (c)  other instruments acceptable to both parties

           Analysis of chromatograph shall comply with the standards set 
           forth in ASTM D 1945. Calculation of the specific gravity from 
           compositional analysis by gas chromatography shall comply with the 
           standards set forth in ASTM D 3588. Measurement of the specific 
           gravity with a gravitometer shall comply with the standards set 
           forth in ASTM D 1070.

     4.3   Flowing Temperature:  Flowing gas temperature shall be 
           continuously measured and used in flow calculations.

Issued by: John A Roscher, Director of Rates & Regulatory Affairs
Issued on: June 6, 2002                       Effective on: August 12, 2002
Filed to comply with order of the Federal Energy Regulatory Commission, Docket 
No. CP01-22-000, et al., issued May 18, 2001, 95 FERC ¶ 61,259
Previous  Next  Search